20 free practice questions for the Grade 2 drinking water treatment operator exam. Many states call this level Class II or Level 2. Tap a choice to see the answer and why. No sign-in needed.
Quick quiz
Take a Grade 2 Water Treatment Quiz
Questions:
Question 1 of 25Equipment Operation and Maintenance
Which of these is predictive maintenance?
Prefer to scroll?
20 Grade 2 Water Treatment Questions on One Page
Question 1 · Equipment Operation and Maintenance
Which of these is predictive maintenance?
Question 2 · Laboratory Analysis
What does a Langelier Saturation Index (LSI) near zero mean?
Question 3 · Security, Safety, and Administrative Procedures
Several customers report an earthy taste on the same afternoon. Compliance results are fine. What follow-up gives the best way to find the cause?
Question 4 · Source Water Characteristics
A well is tested every month at the same pumping rate, and nearby pumping hasn't changed. Its static level is steady, but its pumping level gets deeper each month. What does this point to?
Question 5 · Treatment Process
One filter has a turbidity spike for about 8 minutes every time it comes back from backwash. The other filters are steady, and its media and backwash look normal. Filter-to-waste ends after 3 minutes. What should be tried?
Question 6 · Equipment Operation and Maintenance
A raw-water pump's flow, discharge pressure and motor amps drop, while suction vacuum and vibration go up. Wet-well level is normal, and another pump on the same wet well runs fine. What should be checked first?
Question 7 · Laboratory Analysis
Two hardness results on the same sample don't agree within the lab's limit. Calibration and control checks pass. The second portion was taken after solids started settling in the bottle. What should be done?
Question 8 · Security, Safety, and Administrative Procedures
A new filter interlock has been installed, tested and put in service. The operating SOP still describes the old manual valve steps. What should the supervisor do?
Question 9 · Source Water Characteristics
A forecasted demand peak will require 0.40 MGD of reservoir support for six hours. The downstream tank can accept that support beginning one hour before the peak, and the approved reservoir-release limit is 0.50 MGD. Which plan best fits the forecast and limits?
Question 10 · Treatment Process
Which raw water is the worst fit for direct filtration?
Question 11 · Equipment Operation and Maintenance
What does a pressure-reducing valve do?
Question 12 · Laboratory Analysis
An online chlorine analyzer reads lower than a good grab sample and a second checked analyzer. It passes its zero check but reads low on a certified span standard. What does this mean?
Question 13 · Security, Safety, and Administrative Procedures
What is a backflow preventer for in a drinking-water system?
Question 14 · Source Water Characteristics
A well near the coast shows conductivity and chloride rising whenever it pumps harder, then dropping after it rests. Nearby wells are steady, and another approved source can meet demand. What is the best step?
Question 15 · Treatment Process
A 0.50-MG contact basin treats 2.0 MGD. Its approved baffling factor is 0.40, and the outlet residual is 0.80 mg/L. What CT does the basin provide?
Question 16 · Equipment Operation and Maintenance
In a monthly test, the generator's voltage and frequency settle normally, but it can't carry the essential load. Fuel is fine, and it carried the same load last month. What should be done?
Question 17 · Laboratory Analysis
Which lab result best shows accuracy, not just precision?
Question 18 · Security, Safety, and Administrative Procedures
SCADA shows zero finished-water flow for a four-hour communication outage. Operators wrote down checked totalizer readings at the start and end. What should be done before the monthly report?
Question 19 · Source Water Characteristics
An upstream gauge shows a storm turbidity peak will reach the river intake in about 4 hours and last about 3 hours. An offstream reservoir can supply the plant for 6 hours, and its water is stable. What is the best plan?
Question 20 · Treatment Process
Finished-water iron is rising while raw iron and flow are steady. Iron after the oxidation contact basin is also up, and all four filters rise about the same. Filter turbidity and headloss are normal. What should be checked first?
Keep going
Get Test-Ready with the Full Practice
Operator Master has 100 Grade 2 drinking water treatment questions, free, one at a time with an explanation after each answer.
A printable Grade 2 Water Treatment practice test with 25 questions, an answer key and the formula sheet. Study on paper at work.
What's on the exam
About the Grade 2 Water Treatment Exam
What's on the Grade 2 drinking water treatment operator exam?
Most exams are multiple choice and cover the main parts of the job. Our Grade 2 drinking water treatment practice covers Treatment Process, Equipment Operation and Maintenance, Laboratory Analysis, Source Water Characteristics and Security, Safety, and Administrative Procedures. Grade 2 is the intermediate level, so expect more process control and more math.
Is Grade 2 the same as Class II?
Usually, yes. States name their levels differently: Grade 1 to 4, Class I to IV, Level 1 to 4, or letters such as A to D (in many letter systems, A is the highest). This page is our level 2 of 4. Check your state's guide to see what your state calls each level.
Are these real exam questions?
No. Nobody can share real exam questions. These are practice questions written and reviewed for Operator Master to match the topics operator exams cover. Use them to find what you know and what to study.
Is this practice test free?
Yes. These questions are free with no sign-in. Operator Master has 100 Grade 2 drinking water treatment questions in its free practice, with an explanation after each answer.
Topics in Our Grade 2 Practice
Treatment Process32 questions
Equipment Operation and Maintenance24 questions
Laboratory Analysis16 questions
Source Water Characteristics15 questions
Security, Safety, and Administrative Procedures13 questions