Operator Master/FOG and Pretreatment topics

FOG and Pretreatment · Fats, Oils, and Grease in the Sewer System

How Does FOG Cause Sanitary Sewer Overflows?

A FOG blockage can slow flow, back sewage up into buildings, or cause a sanitary sewer overflow. An overflow can expose the public to sewage, damage property, and pollute streams.

The first job is to follow your utility's overflow response procedure. Protect people, notify the assigned contacts, and control the work area. Stop or reduce the release when you are authorized to, and document conditions. Public and regulator notices must follow the plan and its time frames. Standard federal NPDES permit conditions (40 CFR 122.41(l)(6)) require an oral report within 24 hours of noncompliance that may endanger health or the environment, and a written report within 5 days; your permit governs.

After the response, look at what the evidence shows. Review the removed material, maintenance history, upstream food businesses, recent complaints, rain, pipe defects, and any unusual discharges. One overflow may involve grease, roots, debris, broken pipe, or several of these together.

Fixes may include cleaning, repair, more monitoring, source inspections, outreach, or enforcement. The program that is responsible should choose the action.

Key point: Respond to the overflow first, then investigate the blockage with records and physical evidence.

Check yourself

Practice Questions on This Topic

Tap a choice to see the answer and why.

  1. Question 1 · System O&M and Restoration

    A basin rehab project is finished. What is the best way to tell if it did what it was supposed to do?

  2. Question 2 · System O&M and Restoration

    The number of overflows went down. But total overflow volume and harm to the environment went up. What should you conclude?

  3. Question 3 · System O&M and Restoration

    Why should a renewal program set measurable service targets?

Take a Collections Practice Test

Keep learning

FOG and Industrial Pretreatment for Wastewater Operators

This page comes from the course. It covers why pretreatment matters, fats, oils and grease in the sewer, grease interceptors, industrial permits and local limits, sampling, effects on treatment, inspections, and spill response and records, one step at a time, with short knowledge checks and a certificate of completion.

Take the course

More FOG and Pretreatment Topics

  • What Is the Difference Between Pass Through and Interference?
  • What Does FOG Mean in Wastewater?
  • How Do FOG Deposits Form in Sewers?
  • How Does a Grease Interceptor Separate Grease?
  • Why Must a Grease Interceptor Be Pumped Completely?
  • What Does an Industrial-User Permit Do?
  • What Are Local Limits in Pretreatment?
  • When Is a Grab Sample the Right Sample?
  • What Is a Flow-Proportional Composite Sample?
  • What Is Chain of Custody for Wastewater Samples?
  • What Is a Slug Discharge?