OperatorMaster
WastewaterCollectionsWaterDistribution
Practice examFlashcardsPractice testsBy state
Math CenterAsk KlokFormulasFormula sheetSample questionsBooksiPhone app
All coursesWhere they countFree safety course
For utilities
Premium
OperatorMaster

Free study tools for water and wastewater operators.

AccountSettingsAboutPricing and PaymentFree Practice TestsFormula SheetOperator Salary by StateExam Prep BooksGet the iPhone AppSupportPrivacyTermsExam Disclaimer

Appearance

Operator Master is independent and is not affiliated with WPI, PSI, ABC, the Washington State Department of Ecology or any other state or provincial certification agency.
Operator Master/FOG and Pretreatment topics

FOG and Pretreatment · Why Pretreatment Matters

What Is the Difference Between Pass Through and Interference?

Pass through and interference are two different kinds of failure. Pass through is about the plant's discharge. A pollutant gets through the plant and causes a permit violation. The plant may remove little of that pollutant, or the load may be more than the plant can handle.

Interference is about disruption. A discharge may slow biological treatment, damage equipment, upset solids processing, or prevent the lawful use or disposal of biosolids. Deciding whether interference happened takes plant records, lab results, permit conditions, and the program's own definitions.

One discharge can cause both problems. For example, a toxic waste could weaken biological treatment and let other pollutants pass through. The same event could also contaminate solids or put workers at risk.

Operators help sort this out by saving influent, process, effluent, and solids data. Note what changed first and which units reacted. Let the data, not a first guess, show which problem happened.

Key point: Pass through concerns the plant's discharge; interference concerns disruption of treatment or solids handling.

Check yourself

Practice Questions on This Topic

Tap a choice to see the answer and why.

  1. Question 1 · Laboratory

    An ammonia sample's matrix spike has low recovery. The calibration check, laboratory control sample, and a matrix spike on a different wastewater sample all pass. Which cause is most likely?

  2. Question 2 · Lift Stations and Force Mains

    A lift-station pump's drawdown slows. Inspection later finds long cloth strips wrapped around the impeller. What problem does this finding identify?

  3. Question 3 · Regulations and Compliance

    An industrial discharge is followed by two findings: a pollutant passes through the plant and causes an effluent permit violation, and the biological process is upset enough to disrupt treatment. How should the lead operator describe the findings?

Take a Collections Practice Test

Keep learning

FOG and Industrial Pretreatment for Wastewater Operators

This page comes from the course. It covers why pretreatment matters, fats, oils and grease in the sewer, grease interceptors, industrial permits and local limits, sampling, effects on treatment, inspections, and spill response and records, one step at a time, with short knowledge checks and a certificate of completion.

Take the course

More FOG and Pretreatment Topics

  • What Does FOG Mean in Wastewater?
  • How Do FOG Deposits Form in Sewers?
  • How Does FOG Cause Sanitary Sewer Overflows?
  • How Does a Grease Interceptor Separate Grease?
  • Why Must a Grease Interceptor Be Pumped Completely?
  • What Does an Industrial-User Permit Do?
  • What Are Local Limits in Pretreatment?
  • When Is a Grab Sample the Right Sample?
  • What Is a Flow-Proportional Composite Sample?
  • What Is Chain of Custody for Wastewater Samples?
  • What Is a Slug Discharge?