FOG and Pretreatment · Grease Interceptors and Traps
How Does a Grease Interceptor Separate Grease?
A grease interceptor slows wastewater down so grease can float to the top and heavy solids can sink. Most food fats and oils have a specific gravity of about 0.9, compared with 1.0 for water, so they float. The clearer middle layer then flows on to the sewer. How well this works depends on the device, the plumbing, the wastewater, flow, temperature, and upkeep.
An interceptor is not a treatment plant. What it catches stays inside until someone removes it. As grease and solids fill more space, less room is left for separation, and material can escape downstream.
A grease trap is often a small unit near a sink. A grease interceptor is often larger and placed outside or below ground. Local programs may use these words differently, so use the definitions in your ordinance, permit, or plumbing code. Small units are often hydromechanical, built with baffles and flow control and rated by flow in gallons per minute (gpm), while larger gravity interceptors are rated by liquid volume in gallons.
Focus on whether the device works: correct connections, open inspection points, grease and solids held inside, clear internal parts, and complete maintenance.
Key point: A grease control device works by holding separated material until it is properly removed, not by making grease disappear.
Check yourself
Practice Questions on This Topic
Tap a choice to see the answer and why.
Question 1 · Equipment
A 36-inch interceptor runs half full and can't be bypassed. Which tool measures debris and pipe shape below the water?
Question 2 · Math and Calculations
A 15-inch interceptor flows full at a velocity of 2.5 feet per second (ft/s). What is the flow in million gallons per day (MGD)?
Question 3 · Security, Safety, and Administration
During a FOG inspection at a restaurant, which record best shows the grease interceptor is being kept up?
Question 4 · Sewer System Features
What does a sewer interceptor do?
Question 5 · System O&M and Restoration
A planned diversion will send extra flow into a parallel interceptor. What must be confirmed before the diversion starts?
Keep learning
FOG and Industrial Pretreatment for Wastewater Operators
This page comes from the course. It covers why pretreatment matters, fats, oils and grease in the sewer, grease interceptors, industrial permits and local limits, sampling, effects on treatment, inspections, and spill response and records, one step at a time, with short knowledge checks and a certificate of completion.
Take the course