Odor and H2S · Odor and H2S in Collection Systems

Why Do Force Mains Cause Odor and H2S Problems?

A force main normally flows full, so little air-water surface is available for natural oxygen transfer. Long residence time can allow wastewater to become anaerobic and produce dissolved sulfide.

When the force main discharges, pressure falls and turbulence increases. Hydrogen sulfide can then leave the wastewater rapidly. The discharge structure and the gravity sewer immediately downstream may face strong odors and corrosion.

Changing pump operation can alter residence time, velocity, and discharge pattern. Review pump changes with operations, engineering, and maintenance staff so that odor control does not create capacity, surge, or reliability problems.

Check pump runtime, cycling, discharge noise, gas readings, odor, and downstream corrosion. Write down which pumps operated and the flow condition during the event. Tell the treatment plant and maintenance team when force-main changes may affect incoming wastewater or equipment.

Key point: A force main may form dissolved sulfide upstream and release hydrogen sulfide at its discharge.

Keep learning

Odor Control and Hydrogen Sulfide (H2S) in Wastewater Systems

This page comes from the course. It covers where odors come from, hydrogen sulfide hazards, odor and H2S in collection systems, corrosion, gas detection and worker safety, and odor control in the collection system and at the plant, one step at a time, with short knowledge checks and a certificate of completion.

Take the course